home *** CD-ROM | disk | FTP | other *** search
/ Collection of Tools & Utilities / Collection of Tools and Utilities.iso / dskut / micropls.zip / 1560SPEC.TXT < prev    next >
Text File  |  1990-08-06  |  7KB  |  164 lines

  1.                    MICROPOLIS 1568 DISK DRIVE
  2.                         SPECIFICATIONS
  3.  
  4. Unformatted Capacity:
  5.  
  6.                               Model Number
  7.  
  8.                                    1568-15
  9.  
  10.   Total Mbytes      ------------------ 765 ----------------------
  11.   Disk Platters     -------------------- 8 ----------------------
  12.   Read/Write Heads  ------------------- 15 ----------------------
  13.   Cylinders         ----------------- 1632 ----------------------
  14.   Bytes per track   ---------------- 31250 ----------------------
  15.  
  16. Formatted Capacity (typical)
  17.  
  18.   Total Mbytes      ------------------ 676 ----------------------
  19.   Bytes per Sector  ------------------ 512 ----------------------
  20.   Sectors per Track ------------------- 54 ----------------------
  21.  
  22. PC Drive Types
  23.  
  24.   If you are using third-party installation software or an on-   
  25.   board BIOS on the controller, follow the instructions included
  26.   with the software or controller. Otherwise, examine the entries
  27.   in your system drive table and find the type that most resembles
  28.   the head and cylinder parameters of the drive without exceeding
  29.   these parameters.
  30.  
  31. Performance Specifications
  32.  
  33.   Seek Time (including settling time)     Track-to-Track   4 msec
  34.                                           Average         16 msec
  35.                                           Maximum         35 msec
  36.   Average Rotational Latency                            8.33 msec
  37.   Rotational Speed                              3600 rpm +/- 0.5%
  38.   Data Transfer Rate                                 15 Mbits/sec
  39.   MTBF                                              150,000 hours
  40.   Positioner                     Fully balanced rotary voice coil
  41.   Parking                                 Automatic park and lock
  42.  
  43. General Functional Specifications
  44.  
  45.   Interface                                                  ESDI
  46.   Sectoring (see W1 description, below)              Hard or Soft
  47.   Write Precompensation Start Cylinder                      1632*
  48.   Reduced Write Current Start Cylinder                      1632*
  49.   Landing Zone                                               1632
  50.   Mounting Plane                                  Any orientation
  51.  
  52.   * These  are effectively turned off by specifying a non-existent
  53.   cylinder. Some systems accomplish this by using a value of "-1"
  54.  
  55. Power Requirements
  56.  
  57.   +12V +/-5%                                            2.0A avg.
  58.                                       (4.3A  max during start-up)
  59.   +5V +/-5%                                             1.5A avg.
  60.   Heat dissipation, typical                              29 Watts
  61.  
  62.  
  63. 1560-series drives require the use of an ESDI Controller capable
  64. of a data transfer rate of at least 15 Mbits/sec.
  65.  
  66. Drive Addressing and Interface Termination
  67.  
  68.    NOT
  69.    USED
  70.    J12       J2                J1                  J3
  71.    ____   ________      ___________________   _ _________
  72.   |    | |      |1|    |                 |1| | |  POWER  |
  73.   |    |_|        |____|                   |_| |_________|
  74.   |                                                      |
  75.   |                   RN11          ::::::::             |
  76.   |                                 DDDWWWWW             |
  77.   |                                 AAA54321             |
  78.   |                                 321                  |
  79.   |                                                      |
  80.   |                                                      |
  81.   |                                                      |
  82.   |              (Component Side)                        |
  83.   |                                                     _|
  84.   |                                                    |
  85.   |                                                    |_
  86.   |                                                      |
  87.   |                                                      |
  88.  
  89. The Interface Terminator factory installed at RN11 will provide
  90. proper termination for the interface lines. When daisy-chaining
  91. multiple drives, leave the terminator installed  only in the last
  92. physical drive on the daisy chain cable; remove the terminator from
  93. each of the other drives. In most PC/AT installations, the C: drive
  94. is actually at the end of the cable and should retain the
  95. terminator.
  96.  
  97. The drive address jumpers are identified as DA1,DA2 and DA3.
  98. Address selection is binary, as shown in the table below. The ESDI
  99. controllers's documentation will specify the drive address to use.
  100.  
  101.    Drive            Select Jumpers
  102.   Address        DA3     DA2     DA1
  103.   -------        ---     ---     ---
  104.      1           out     out      in
  105.      2           out      in     out
  106.      3           out      in      in
  107.      4            in     out     out
  108.      5            in     out      in
  109.      6            in      in     out
  110.      7            in      in      in
  111.  
  112. "Drive address 0" (no jumper at DA1,DA2, or DA3) is a "deselect"
  113. (i.e., no drive selected).
  114.  
  115. Drives are factory configured as Drive Address 1.
  116.  
  117. For many multiple drive installations,each drive must have a unique
  118. address. An exception is that for every drive in a PC/AT
  119. installation, verify that only Drive Address is at DA2; move the
  120. jumper if necessary (the special twisted interface cable that is
  121. generally used takes care  of assigning a unique address to each
  122. drive). PC/AT controller can typically support a maximum of two
  123. drives.
  124.  
  125. * W5 selects the spindle a control option. If W5 is installed, The
  126. drive waits for a Start Spindle command(after power is applied) to
  127. start the spindle motor.
  128.  
  129. If W5 is not installed (the factory default configuration),the
  130. drive automatically starts the spindle motor at power-on. W5 is not
  131. installed for PC/AT applications.
  132.  
  133. * W1 selects  the sectoring mode. If W1 is installed , the drive
  134. operates in the soft-sectored mode.
  135.  
  136. If W1 is not installed(the factory default configuration), the
  137. Drive operates in the hard-sector mode. W1 is not install for most
  138. PC/AT in applications.
  139.  
  140. W28 is for the Frame ground option.
  141.  
  142. * The number of bytes per sector may be specified using the Set
  143. Bytes Per Sector command or by selecting a default sector
  144. configuration with jumpers W2, W3, and W4 as follows:
  145.  
  146.        Jumpers            Sectors            Bytes/Sector
  147.     W4    W3    W2       Per Track       Formatted  Unformatted
  148.     ---   ---   ---      ---------       ---------  -----------
  149.     out   out   out         53              512          588
  150.  -------------------------------------------------------------
  151. | * out   out    in         54              512          576  |
  152.  -------------------------------------------------------------
  153.     out    in   out         28             1024         1116
  154.     out    in    in         14             2048         2232
  155.      in   out   out          7             4096         4464
  156.      in   out    in                     (Reserved)          
  157.      in    in   out         97              256          321
  158.      in    in    in          1           31,248       31,248
  159.  
  160.  * This is the default (factory installed) configuration and is
  161. recommended for PC/AT applications